Remote control equipment RCE 2000PDF, 257.3 KB
PurposeThe remote control equipment (RCE) RCE 2000 is intended for remote control and monitoring of ground navigation and communication equipment state: DF 2000 automatic direction finder, DVOR 2000 azimuthal doppler radio beacon, DME 2000 distancemeasuring radio beacon, TRS 2000 automated receiving and transmitting centre, ILS 2000 instrumental landing system, MLS 2000 microwave landing system, DME 2100 landing system long-range radio beacon, and VOR 2100 course all-direction radio beacon.
FunctionThe function of the RCE 2000 is based on the organization of uninterrupted data exchange by means of software and hardware solutions to provide efficient state control and monitoring of the devices. Data exchange with the devices is realized in real time mode via separate physical communication lines. RCE CompositionThe RCE consists of: remote control rack and a set of connection cables. All the devices are mounted inside the 19″ rack. ControlControl of the RCE and the equipment under monitoring can be exercise control using the touch manipulator of the keyboard or with the sensor screen of the monitor by means of a screen graphic interface. All the equipment have a similar graphic interface and their own windows of control and monitoring. The parameters and the state of the equipment under monitoring are displayed in graphic mode on the colour monitor. Changes in the state or the parameters are accompanied by appropriate light and sound signalization. The RCE 2000 provides access to the information about the state of the equipment under monitoring via the local network Ethernet using TCP/IP protocol, or via the ATN network in accordance with CCITT X.25 protocol if necessary. Monitoring and
| |||||||||||||||||||||||||||||||||||||||||||||
| Number of devices under monitoring, up to | 8 |
| Length of the physical communication line between the RCE equipment and the airfield equipment under monitoring, up to | 10 km |
| Type of physical communication line between the RCE and airfield equipment under monitoring | two 4-wire physical communication lines (main and back-up) |
| Data transfer reliability | 10−9 |
| Number of communication channels with AATC system: | |
| via RS-232 interface | 2 |
| via RS-485 interface | 2 |
| Distance between RCE and ATCAS, up to: | |
| via RS-232 interface | 15 m |
| via RS-485 interface | 1200 m |
Dimensions | |
| RCE Rack (width × height × depth) | 600 × 1600 × 800 mm |
Power Supply | |
| Main network | 220 (+10 %; -15 %) V, 50 Hz |
| Power consumption, at most | 600 W |
| Operational time from UPS, at least | 30 minutes |
Operating Conditions | |
| Environment temperature | 5°Ñ to 40°Ñ |
| Relative humidity (at temperature under +25°Ñ), at most | 98 % |
Reliability | |
| MTBF, at least | 50 000 hours |
| Life cycle | 15 years |